Skip to main navigation Skip to search Skip to main content

Antegrade Superficial Femoral Artery Approach Using Manual Compression and 4-F Delivery System for Infrainguinal Occlusive Disease

  • Bahaa Nasr
  • , Alexandra Hauguel
  • , Cédric Yven
  • , Romain Didier
  • , Pierre Gouny
  • , Yann Gouëffic
  • Service d'Hématologie Biologique
  • Groupe Hospitalier Saint-joseph

Research output: Contribution to journalArticlepeer-review

4 Citations (Scopus)

Abstract

Background: This study sought to assess the feasibility and safety of antegrade superficial femoral artery (SFA) duplex-guided puncture using a 4-F catheter sheath and manual compression for the treatment of infrainguinal occlusive lesions. Methods: From March 2017 to March 2019, all patients who underwent endovascular treatment employing an antegrade SFA approach for femoropopliteal or below-the-knee lesions were included in this study. Follow-up included clinical and duplex ultrasound examinations at 1 month. The primary endpoint was the frequency of major complications at the puncture site. Results: In all, 71 procedures were performed in 70 patients (46 men; mean age: 79.1 ± 11.5 years), most of whom presented with critical limb-threatening ischemia (n = 59; 83%). Of these 71 procedures, 35 (49.3%) were performed for isolated femoropopliteal lesions and 24 (33.8%) for multilevel lesions. The primary endpoint was observed in 4 patients (5.6%). There were 3 observed hematomas (4.2%): 2 required surgical treatment, and 1 necessitated transfusion without intervention. At 30 days, we reported 1 pseudoaneurysm (1.4%). Conclusions: Our results showed that antegrade SFA puncture is feasible and safe with duplex ultrasound guidance and use of a 4-F catheter sheath.

Original languageEnglish
Pages (from-to)1-8
Number of pages8
JournalAnnals of Vascular Surgery
Volume78
DOIs
Publication statusPublished - 1 Jan 2022
Externally publishedYes

Fingerprint

Dive into the research topics of 'Antegrade Superficial Femoral Artery Approach Using Manual Compression and 4-F Delivery System for Infrainguinal Occlusive Disease'. Together they form a unique fingerprint.

Cite this