Characterization of a CdTe microstrip detector as a hard X ray focal plane prototype

E. Caroli, N. Auricchio, A. Donati, F. Schiavone, J. B. Stephen, G. Ventura, S. Del Sordo, G. Agnetta, F. Russo, M. Zora, G. Bertuccio, S. Caccia, M. Sampietro, E. Gombia, G. Pareschi, B. Negri

Research output: Contribution to journalConference articlepeer-review

Abstract

Our collaboration is developing a hard X-ray telescope operating in the 10-100 keV energy range and based on focusing multi-layers coupled to a CdTe/CZT focal plane detector. Two classes of detectors can comply with the focal plane requirements: pixel detectors, where an electrode is segmented as a bi-dimensional array and micro-strip detectors. In the last ones each of the opposite crystal surfaces contains a set of orthogonal micro-strips. This geometry reduces noticeably the number of readout independent channels even if it requires the coincidence among at least two opposite strips to determine the position. In the current work we present the characterization of the spectroscopic and spatial response of CdTe prototype (1 cm2) equipped with two orthogonal micro-strip electrodes with 0.5 mm pitch and mounted on an alumina substrate using both collimated and un-collimated radioactive sources. The 16 anode strips use, as front-end analogical electronics, an innovative low noise and low power dissipation (<1 mW/ch) ASIC, whereas the cathode strips pulses are readout by 16 charge sensitive preamplifiers. The handling and acquisition electronics implements a gamma camera logic, where the equivalent of 256 channels are acquired and converted via 4 ADC and afterwards sent to a 32 bit parallel interface. This system calculates a weighted average of the signals from the irradiated strips to determine the mean position and the energy of the interaction. The comparison between these results and those obtained with an equivalent pixel detector should allow to decide the definitive design of the hard X ray focal plane detector.

Original languageEnglish
Pages (from-to)4378-4382
Number of pages5
JournalIEEE Nuclear Science Symposium Conference Record
Volume7
Publication statusPublished - 1 Dec 2004
Externally publishedYes
Event2004 Nuclear Science Symposium, Medical Imaging Conference, Symposium on Nuclear Power Systems and the 14th International Workshop on Room Temperature Semiconductor X- and Gamma- Ray Detectors - Rome, Italy
Duration: 16 Oct 200422 Oct 2004

Fingerprint

Dive into the research topics of 'Characterization of a CdTe microstrip detector as a hard X ray focal plane prototype'. Together they form a unique fingerprint.

Cite this