Skip to main navigation Skip to search Skip to main content

Characterization of frp-to-concrete bonded interface: Description of the single lap shear test

Research output: Contribution to journalArticlepeer-review

Abstract

The single lap shear test is an experimental method available for the characterization of FRP-to-concrete bonded interfaces. The obtained experimental results are required for the determination of parameters used in the design of concrete structures reinforcement or repairing by bonding composite materials. The aim of this article is to precisely describe the test procedure and experimental scatter. The test procedure has since been adopted for several investigations revealing its suitability and robustness for many different reinforcement processes.

Original languageEnglish
Pages (from-to)1073-1082
Number of pages10
JournalEuropean Journal of Environmental and Civil Engineering
Volume13
Issue number9
DOIs
Publication statusPublished - 1 Jan 2009
Externally publishedYes

Keywords

  • Anchorage
  • Composite bonding
  • Concrete reinforcement
  • Shear test

Fingerprint

Dive into the research topics of 'Characterization of frp-to-concrete bonded interface: Description of the single lap shear test'. Together they form a unique fingerprint.