Skip to main navigation Skip to search Skip to main content

Characterization of Hydrogenated Amorphous Silicon Detectors With Clinical Photon and Electron Beams

  • M. Ponzecchi
  • , K. Kanxheri
  • , L. Servoli
  • , M. V. Rossi
  • , E. Gazzera
  • , G. Insero
  • , S. Pallotta
  • , M. Fabi
  • , C. Grimani
  • , F. Sabbatini
  • , M. Villani
  • , S. Aziz
  • , L. Calcagnile
  • , A. P. Caricato
  • , M. Martino
  • , G. Maruccio
  • , A. G. Monteduro
  • , G. Quarta
  • , S. Rizzato
  • , R. Catalano
  • G. A.P. Cirrone, G. Cuttone, M. Guarrera, G. Petringa, L. Frontini, V. Liberali, A. Stabile, M. M.S. Vasquez, F. Cittadini, T. Croci, M. Ionica, M. Menichelli, A. Morozzi, D. Passeri, M. Pedio, F. Peverini, P. Placidi, N. Zema, D. Caputo, G. De Cesare, N. Lovecchio, A. Nascetti, M. Cazzanelli, H. Hasnaoui, M. Polo, A. Quaranta, D. Calvo, R. Cirio, P. De Remigis, F. Lenta, G. Mazza, R. J. Wheadon, S. Dunand, G. Konstantinou, N. Wyrsch, B. Loris, A. Bashiri, M. Large, M. Petasecca, C. Talamonti
  • University of Florence
  • Istituto Nazionale di Fisica Nucleare, Sezione di Firenze
  • INFN Sezione di Perugia
  • University of Perugia
  • University of Urbino Carlo Bo
  • Sezione di Lecce
  • University of Salento
  • INFN-LNS
  • Sezione INFN di Milano
  • University of Milano
  • University of Padova
  • International School for Advanced Studies (SISSA/ISAS)
  • Consiglio Nazionale delle Ricerche
  • Sezione di Roma
  • University of Rome
  • Università di Trento
  • INFN Sezione di Torino
  • Politecnico di Torino
  • ENAC-IIC-GEL
  • University of Wollongong
  • Najran University

Research output: Contribution to journalArticlepeer-review

Abstract

Flexible hydrogenated amorphous silicon (a-Si:H) detectors are attractive candidates for clinical dosimetry, particularly for applications requiring lightweight devices and operation without external bias. In this work, three flexible a-Si:H detector architectures are experimentally compared under clinical photon and electron beams: a conventional n-i-p diode, a charge selective contact (CSC) detector, and a very thin p-i-n diode. All detectors show excellent dose linearity under both irradiation modalities. However, large differences in sensitivity are observed at zero bias, exceeding two orders of magnitude across architectures. The conventional n-i-p device shows a response that is limited by the internal electric field, while CSC and very thin p-i-n detectors achieve sensitivities in the pC/cGy range without applied bias. Electron beams yield higher charge per unit dose than photons, compatible with a larger local energy deposition in the active layer. The results demonstrate that sensitivity in flexible a-Si:H dosimeters is governed by contact design and intrinsic layer thickness rather than by active volume alone. Taken together, the present results suggest that combining charge selective contacts with thinner intrinsic layers may represent a promising strategy to further enhance zero-bias sensitivity. These findings provide clear design guidelines for the development of flexible dosimeters for surface and transmission measurements in advanced radiotherapy.

Original languageEnglish
JournalIEEE Sensors Journal
DOIs
Publication statusAccepted/In press - 1 Jan 2026
Externally publishedYes

Keywords

  • CSC detector
  • hydrogenated amorphous silicon
  • p-i-n detector
  • sensitivity

Fingerprint

Dive into the research topics of 'Characterization of Hydrogenated Amorphous Silicon Detectors With Clinical Photon and Electron Beams'. Together they form a unique fingerprint.

Cite this