Complementary study of differential absorption lidar optimization in direct and heterodyne detections

Research output: Contribution to journalArticlepeer-review

Abstract

A detailed study using both analytical and numerical calculations of direct and heterodyne differential absorption lidar (DIAL) techniques is conducted to complement previous studies. The DIAL measurement errors depend on key experimental parameters, some of which can be adjusted to minimize the statistical error. Accordingly, the pertinent criteria on optical thickness, the number of photons emitted at the on and off wavelengths, are discussed to reduce the relative error on the total column content or range-resolved measurements that rely on either hard target or atmospheric backscatter returns. In direct detection, the optimal optical thickness decreases from 1.3 to 0.8 when the background increases while the on-line-to-off-line optimal energy ratio decreases from 3.6 to 2.7. In heterodyne detection, the minimum error is obtained for an optical thickness of 1.2 and an energy ratio of 4.3.

Original languageEnglish
Pages (from-to)4898-4908
Number of pages11
JournalApplied Optics
Volume45
Issue number20
DOIs
Publication statusPublished - 10 Jul 2006

Fingerprint

Dive into the research topics of 'Complementary study of differential absorption lidar optimization in direct and heterodyne detections'. Together they form a unique fingerprint.

Cite this