T1 - Contribution of the periosteum to mandibular distraction
AU - Debelmas, Alexandre
AU - Picard, Arnaud
AU - Kadlub, Natacha
AU - Boisson, Jean
N1 - Publisher Copyright:
© 2018 Debelmas et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2018/6/1
Y1 - 2018/6/1
N2 - Mandibular distraction is a surgical process that progressively lengthens bone. To improve the distraction procedure and devices, the load of distraction and the mechanical strain of soft tissues during the process must be determined. We tested the assumption that it could be the periosteum primarily opposing distraction. Therefore we assessed the mechanical properties of the human mandibular periosteum and compared the stress-strain data with the torque measured on the activator during a cadaveric mandibular distraction. A 20 mm horizontal mandibular distraction was performed in 7 cadavers using standard distractors. Torque was measured with a torquemeter placed on the activation rods of the devices, providing a load (Lt) for each millimeter of distraction. In parallel, 18 periosteum samples were harvested from 9 cadaver mandibles. Uniaxial tensile tests were performed on the specimens and an estimated load (Lc) was calculated using periosteal stress-strain data and mandibular dimensions. During the distraction process, we observed an increase of the load Lt from 11.6 to 50.6 N. The periosteum exhibited a nonlinear viscoelastic stress-strain relationship, typical of biological tissues composed of collagen and elastin. The median Lc and Lt were not significantly different for the first millimeter of distraction. We demonstrated the periosteum is primarily responsible for opposing the distraction load.
AB - Mandibular distraction is a surgical process that progressively lengthens bone. To improve the distraction procedure and devices, the load of distraction and the mechanical strain of soft tissues during the process must be determined. We tested the assumption that it could be the periosteum primarily opposing distraction. Therefore we assessed the mechanical properties of the human mandibular periosteum and compared the stress-strain data with the torque measured on the activator during a cadaveric mandibular distraction. A 20 mm horizontal mandibular distraction was performed in 7 cadavers using standard distractors. Torque was measured with a torquemeter placed on the activation rods of the devices, providing a load (Lt) for each millimeter of distraction. In parallel, 18 periosteum samples were harvested from 9 cadaver mandibles. Uniaxial tensile tests were performed on the specimens and an estimated load (Lc) was calculated using periosteal stress-strain data and mandibular dimensions. During the distraction process, we observed an increase of the load Lt from 11.6 to 50.6 N. The periosteum exhibited a nonlinear viscoelastic stress-strain relationship, typical of biological tissues composed of collagen and elastin. The median Lc and Lt were not significantly different for the first millimeter of distraction. We demonstrated the periosteum is primarily responsible for opposing the distraction load.
UR - https://www.scopus.com/pages/publications/85049149521
U2 - 10.1371/journal.pone.0199116
DO - 10.1371/journal.pone.0199116
M3 - Article
C2 - 29953443
AN - SCOPUS:85049149521
SN - 1932-6203
VL - 13
JO - PLoS ONE
JF - PLoS ONE
IS - 6
M1 - e0199116
ER -