TY - JOUR
T1 - Digital histology with Mueller microscopy
T2 - How to mitigate an impact of tissue cut thickness fluctuations
AU - Lee, Hee Ryung
AU - Li, Pengcheng
AU - Yoo, Thomas Sang Hyuk
AU - Lotz, Christian
AU - Groeber-Becker, Florian Kai
AU - Dembski, Sofia
AU - Garcia-Caurel, Enric
AU - Ossikovski, Razvigor
AU - Ma, Hui
AU - Novikova, Tatiana
N1 - Publisher Copyright:
© The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
PY - 2019/7/1
Y1 - 2019/7/1
N2 - Mueller microscopy studies of fixed unstained histological cuts of human skin models were combined with an analysis of experimental data within the framework of differential Mueller matrix (MM) formalism. A custom-built Mueller polarimetric microscope was used in transmission configuration for the optical measurements of skin tissue model adjacent cuts of various nominal thicknesses (5 to 30 μm). The maps of both depolarization and polarization parameters were calculated from the corresponding microscopic MM images by applying a logarithmic Mueller matrix decomposition (LMMD) pixelwise. The parameters derived from LMMD of measured tissue cuts and the intensity of transmitted light were used for an automated segmentation of microscopy images to delineate dermal and epidermal layers. The quadratic dependence of depolarization parameters and linear dependence of polarization parameters on thickness, as predicted by the theory, was confirmed in our measurements. These findings pave the way toward digital histology with polarized light by presenting the combination of optimal optical markers, which allows mitigating the impact of tissue cut thickness fluctuations and increases the contrast of polarimetric images for tissue diagnostics.
AB - Mueller microscopy studies of fixed unstained histological cuts of human skin models were combined with an analysis of experimental data within the framework of differential Mueller matrix (MM) formalism. A custom-built Mueller polarimetric microscope was used in transmission configuration for the optical measurements of skin tissue model adjacent cuts of various nominal thicknesses (5 to 30 μm). The maps of both depolarization and polarization parameters were calculated from the corresponding microscopic MM images by applying a logarithmic Mueller matrix decomposition (LMMD) pixelwise. The parameters derived from LMMD of measured tissue cuts and the intensity of transmitted light were used for an automated segmentation of microscopy images to delineate dermal and epidermal layers. The quadratic dependence of depolarization parameters and linear dependence of polarization parameters on thickness, as predicted by the theory, was confirmed in our measurements. These findings pave the way toward digital histology with polarized light by presenting the combination of optimal optical markers, which allows mitigating the impact of tissue cut thickness fluctuations and increases the contrast of polarimetric images for tissue diagnostics.
KW - Mueller polarimetry
KW - digital histology
KW - logarithmic decomposition
KW - skin tissue models
U2 - 10.1117/1.JBO.24.7.076004
DO - 10.1117/1.JBO.24.7.076004
M3 - Article
C2 - 31347339
AN - SCOPUS:85070592760
SN - 1083-3668
VL - 24
JO - Journal of Biomedical Optics
JF - Journal of Biomedical Optics
IS - 7
M1 - 076004
ER -