Abstract
In this study, we presents the results of hydrodynamic impact tests performed with the shock machine at ENSTA Brittany, by integrating a device allowing to generate bubbles in the tank. During these tests, the average void fractions considered are between 0.35 and 1.1%. Our results highlight a significant reduction of the impact force with the increase of the void fraction.
| Translated title of the contribution | On the influence of aeration on water entry problems: Experiments and simulations |
|---|---|
| Original language | French |
| Pages (from-to) | 74-80 |
| Number of pages | 7 |
| Journal | Houille Blanche |
| Volume | 2019-December |
| Issue number | 5-6 |
| DOIs | |
| Publication status | Published - 1 Dec 2019 |
Fingerprint
Dive into the research topics of 'On the influence of aeration on water entry problems: Experiments and simulations'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver