Skip to main navigation Skip to search Skip to main content

Mise en œuvre de capteurs de turbidité en collecteurs d'assainissement

Translated title of the contribution: Implementation of turbidity sensors in sewer systems
  • C. Joannis
  • , G. Ruban
  • , M. Aumond
  • , J. L. Bertrand-Krajewski
  • , P. Battaglia
  • , C. Lacour
  • , M. Saad
  • , G. Chebbo

Research output: Contribution to journalArticlepeer-review

Abstract

This paper presents possible objectives for turbidity monitoring in sewerage, and provides details on key issues for getting reliable and accurate turbidity measurements. It relies on the experience gathered during their field work by four French research teams. The topics considered here are the choice of a sensor, calibration procedures, the choice of a measuring site, different in situ implementation modes, sampling strategy, maintenance and uncertainty assessment. A brief description of a few case studies follow up this overview.

Translated title of the contributionImplementation of turbidity sensors in sewer systems
Original languageFrench
Pages (from-to)21-31
Number of pages11
JournalTechniques - Sciences - Methodes
Issue number1-2
DOIs
Publication statusPublished - 1 Jan 2010
Externally publishedYes

Fingerprint

Dive into the research topics of 'Implementation of turbidity sensors in sewer systems'. Together they form a unique fingerprint.

Cite this