Predicting the performance of the CMS precision PbWO4 electromagnetic calorimeter in the HL-LHC era from test beam results on irradiated crystals

Research output: Contribution to journalArticlepeer-review

Abstract

The harsh radiation environment, in which detectors will have to operate during the high luminosity phase of the Large Hadron Collider, represents a crucial challenge for many calorimeter technologies. In the Compact Muon Solenoid (CMS) forward calorimeters, ionizing doses and hadron fluences will reach up to 300 kGy (at a dose rate of 30 Gy/h) and ${2\times 10^{14} cm^{-2}}$ , respectively, at the pseudorapidity region of $\vert \eta \vert $ = 2.6. To evaluate the evolution of the CMS electromagnetic calorimeter performance in such conditions, a set of PbWO4 crystals, which had previously been exposed to 24 GeV protons up to integrated fluences between ${2.1\times 10^{13} cm^{-2}}$ and ${1.3\times 10^{14} cm^{-2}}$ , has been studied in beam tests. A degradation of the energy resolution and a nonlinear response to electron showers are observed in damaged crystals. Direct measurements of the light output from the crystals show the amplitude decreasing and pulse becoming faster as the fluence increases. The evolution of the performance of the PbWO4 crystals has been well understood and parameterized in terms of increasing light absorption inside the crystal volume. A double-sided readout configuration, in which two identical photodetectors are coupled to the opposite ends of each crystal, has also been tested. The separate and simultaneous readout of the light from the two sides of the crystal allows us to correct for longitudinal shower fluctuations and to mitigate the degradation of energy resolution in highly damaged crystals. The nonlinear response to electromagnetic showers, arising from high nonuniformity of light collection efficiency along the longitudinal axis of irradiated crystals, can also be corrected by means of the double-sided readout technique.

Original languageEnglish
Article number8253465
Pages (from-to)2068-2072
Number of pages5
JournalIEEE Transactions on Nuclear Science
Volume65
Issue number8
DOIs
Publication statusPublished - 1 Aug 2018

Keywords

  • Calorimetry
  • Compact Muon Solenoid (CMS)
  • Large Hadron Collider (LHC)
  • energy resolution
  • high energy physics instrumentation
  • light loss
  • radiation damage of crystals

Fingerprint

Dive into the research topics of 'Predicting the performance of the CMS precision PbWO4 electromagnetic calorimeter in the HL-LHC era from test beam results on irradiated crystals'. Together they form a unique fingerprint.

Cite this