Abstract
An up to 15 T pulsed magnetic field generator in a volume of a few cubic centimeters has been developed for experiments with magnetized laser plasma. The magnetic field is created by a pair of coils placed in a sealed reservoir with liquid nitrogen, installed in a vacuum chamber with a laser target. The bearing body provides the mechanical strength of the system both in the case of co-directional and oppositely connected coils. The configuration of the housing allows laser radiation to be introduced into the working area between the coils in a wide range of directions and focusing angles, places targets away from the symmetry axis of the magnetic system, and irradiates several targets simultaneously.