Real-life outcomes of the PAUL® Glaucoma Implant with ripcord in refractory glaucoma

  • V. Heintz
  • , P. Bastelica
  • , C. Baudouin
  • , A. Rousseau
  • , M. Labetoulle
  • , B. Bodaghi
  • , L. Debillon
  • , A. Vest
  • , Y. Chami
  • , A. Lecannuet
  • , M. Bouvet
  • , H. Lama
  • , A. Bistour
  • , A. Brézin
  • , A. Labbé
  • , Y. Lachkar

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: This study aimed to evaluate the one-year efficacy and safety of the PAUL® Glaucoma Implant with ripcord for treating refractory glaucoma. Methods: Conducted between November 2021 and September 2023 across five hospitals in Île-de-France, France, the study included patients with refractory glaucoma who underwent stand-alone implantation of the PAUL® Glaucoma Implant with a ripcord technique. Two success criteria were assessed at 12 months: (1) complete success: intraocular pressure (IOP) ≤ 21 mmHg with a ≥ 20% reduction in IOP without IOP-lowering medications, no additional filtering surgery, no chronic hypotony, defined as an IOP ≤ 5 mmHg measured at two successive visits 3 months apart, and no loss of light perception; (2) qualified success: same criteria as complete success but with the same or fewer IOP-lowering medications. Results: The study evaluated 41 eyes of 41 patients, all of whom had undergone at least one previous glaucoma surgery (mean 1.7 surgeries per patient) and a mean visual field deviation of −15.7 dB. At 12 months, 39.0% of patients achieved complete success; 97.6% achieved qualified success. No additional filtering surgeries were required. The mean IOP decreased significantly from 28.7 mmHg to 12.6 mmHg (−53.0%, P < 0.0001), and the mean number of IOP-lowering medications decreased from 3.9 to 1.2 (−69.4%, P < 0.0001). Complications included transient hypotony in one patient (2.4%), spontaneously resolving choroidal detachment in seven patients (17.1%), tube exposure in one patient (2.4%), and diffuse corneal edema in two patients (4.9%). Conclusion: The PAUL® Glaucoma Implant with ripcord appears safe and effective, reducing the risk of early postoperative hypotony and allowing further minimally invasive IOP-lowering during follow-up.

Translated title of the contributionRésultats en vie réelle de l'implant de PAUL® avec ripcord dans le glaucome réfractaire
Original languageEnglish
Article number104783
JournalJournal Francais d'Ophtalmologie
Volume49
Issue number3
DOIs
Publication statusPublished - 1 Mar 2026
Externally publishedYes

Keywords

  • Glaucoma
  • Glaucoma drainage implants
  • Glaucome
  • Implants de drainage
  • Intraocular pressure
  • Pression intraoculaire

Fingerprint

Dive into the research topics of 'Real-life outcomes of the PAUL® Glaucoma Implant with ripcord in refractory glaucoma'. Together they form a unique fingerprint.

Cite this