Abstract
We study the capillary instability of a liquid film (thickness h0 coating a horizontal cylindrical tube (radius R0). We show experimentally that the instability only occurs if h0/R0 > 0.3(R0/a)2, where a is the capillary length. If this criterion is not fulfilled, the liquid film does not destabilize into an array of drops, owing to the gravitational drainage.
| Original language | English |
|---|---|
| Pages (from-to) | 217-226 |
| Number of pages | 10 |
| Journal | Journal of Fluid Mechanics |
| Volume | 556 |
| DOIs | |
| Publication status | Published - 10 Jun 2006 |
| Externally published | Yes |
Fingerprint
Dive into the research topics of 'The effects of gravity on the capillary instability in tubes'. Together they form a unique fingerprint.Cite this