Abstract
The aim of this letter is to study, by using a time-reversal mirror (TRM), ways to overcome the distortions induced by multipaths in an acoustic transmission. A set of experiments is performed with a TRM made of 96 reversible transducers and results will be presented. One result is related to the high focusing property obtained with a TRM working in a bounded channel. It will be shown that the time-reversed beam is much thinner than the one measured in an unbounded medium. The second result concerns the time compression observed for the time-reversed acoustic pulse. The influence of the number of TRM elements on the time compression is discussed.
| Original language | English |
|---|---|
| Pages (from-to) | 1811-1813 |
| Number of pages | 3 |
| Journal | Applied Physics Letters |
| Volume | 70 |
| Issue number | 14 |
| DOIs | |
| Publication status | Published - 7 Apr 1997 |
| Externally published | Yes |