The aim of this letter is to study, by using a time-reversal mirror (TRM), ways to overcome the distortions induced by multipaths in an acoustic transmission. A set of experiments is performed with a TRM made of 96 reversible transducers and results will be presented. One result is related to the high focusing property obtained with a TRM working in a bounded channel. It will be shown that the time-reversed beam is much thinner than the one measured in an unbounded medium. The second result concerns the time compression observed for the time-reversed acoustic pulse. The influence of the number of TRM elements on the time compression is discussed.