Abstract
The wavefront of an injection-seeded soft x-ray laser beam generated by amplification of high-harmonic pulses in a λ = 18.9 nm molybdenum plasma amplifier was measured by a Hartmann wavefront sensor with an accuracy of λ/32 root mean square (rms). A significant improvement in wavefront aberrations of 0.51 ± 0.03λ rms to 0.23 ± 0.01λ rms was observed as a function of plasma column length. The variation of wavefront characteristic as a function time delay between the injection of the seed and peak of soft x-ray amplifier pump was studied. The measurements were used to reconstruct the soft x-ray source and confirm its high peak brightness.
| Original language | English |
|---|---|
| Pages (from-to) | 4011-4014 |
| Number of pages | 4 |
| Journal | Optics Letters |
| Volume | 38 |
| Issue number | 20 |
| DOIs | |
| Publication status | Published - 15 Oct 2013 |
Fingerprint
Dive into the research topics of 'Wavefront improvement in an injection-seeded soft x-ray laser based on a solid-target plasma amplifier'. Together they form a unique fingerprint.Cite this