Cleopatra: a 12-channel recycling integrator ASIC for the readout of hydrogenated amorphous silicon detectors in radiotherapy dosimetry

  • G. Mazza
  • , R. Wheadon
  • , F. Lenta
  • , C. Buti
  • , M. Fabi
  • , C. Grimani
  • , S. Pallotta
  • , F. Sabbatini
  • , C. Talamonti
  • , M. Villani
  • , S. Aziz
  • , L. Calcagnile
  • , A. P. Caricato
  • , M. Martino
  • , G. Maruccio
  • , A. G. Monteduro
  • , G. Quarta
  • , S. Rizzato
  • , R. Catalano
  • , G. A.P. Cirrone
  • G. Cuttone, M. C. Guarrera, G. Petringa, L. Frontini, V. Liberali, A. Stabile, M. Vasquez, T. Croci, M. Ionica, K. Kanxheri, M. Menichelli, A. Morozzi, F. Moscatelli, D. Passeri, M. Pedio, F. Peverini, P. Placidi, L. Servoli, L. Tosti, N. Zema, D. Caputo, G. De Cesare, N. Lovecchio, A. Nascetti, D. Calvo, R. Cirio, P. De Remigis, S. Dunand, J. E. Thomet, M. Large, M. Petasecca, A. Bashiri, L. Piccolo, N. Wyrsch
  • INFN Sezione di Torino
  • Politecnico di Torino
  • Istituto Nazionale di Fisica Nucleare, Sezione di Firenze
  • University of Florence
  • University of Urbino Carlo Bo
  • Sezione di Lecce
  • University of Salento
  • INFN-LNS
  • Sezione INFN di Milano
  • University of Milano
  • INFN Sezione di Perugia
  • University of Perugia
  • International School for Advanced Studies (SISSA/ISAS)
  • Consiglio Nazionale delle Ricerche
  • Sezione di Roma
  • University of Rome “Tor Vergata”
  • ENAC-IIC-GEL
  • University of Wollongong
  • Najran University

Résultats de recherche: Contribution à un journalArticleRevue par des pairs

Résumé

The Cleopatra ASIC is a 12-channel prototype ASIC for the readout of hydrogenated amorphous silicon sensors used for real-time dosimetry in radiation diagnostic and radiation therapy. The architecture is based on a current to frequency conversion based on the recycling integrator principle in order to cover a dynamic range of four orders of magnitude with high linearity. Three different input amplifier configurations have been implemented in order to check the trade-off between detector capacitance and maximum output frequency. Cleopatra has been designed in CMOS 28 nm technology and succesfully tested in laboratory.

langue originaleAnglais
Numéro d'articleC01034
journalJournal of Instrumentation
Volume20
Numéro de publication1
Les DOIs
étatPublié - 1 janv. 2025
Modification externeOui

Empreinte digitale

Examiner les sujets de recherche de « Cleopatra: a 12-channel recycling integrator ASIC for the readout of hydrogenated amorphous silicon detectors in radiotherapy dosimetry ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation