Passer à la navigation principale Passer à la recherche Passer au contenu principal

Crack initiation and propagation in braided SiC/SiC composite tubes: Effect of braiding angle

  • Université Paris-Saclay
  • CNRS
  • Synchrotron SOLEIL

Résultats de recherche: Contribution à un journalArticleRevue par des pairs

37 Citations (Scopus)

Résumé

Crack initiation and propagation in three braided SiC/SiC composite tubes with different braiding angles are investigated by in situ tensile tests with synchrotron micro-computed tomography. Crack networks are precisely detected after an image subtraction procedure based on Digital Volume Correlation. FFT based simulations are performed on the full-resolution 3D images to assess elastic stress/strain fields. Quantitative measurements of the crack geometries are performed using a novel method based on grey levels. The results show that braiding angle has no obvious effect on the location of crack onsets (initiation always occurs at tow interfaces), whereas it significantly affects the paths of crack propagation. This work provides an explicit demonstration of the crack propagation scenarios with respect to the mesoscopic fibre architectures.

langue originaleAnglais
Pages (de - à)4403-4418
Nombre de pages16
journalJournal of the European Ceramic Society
Volume40
Numéro de publication13
Les DOIs
étatPublié - 1 oct. 2020

Empreinte digitale

Examiner les sujets de recherche de « Crack initiation and propagation in braided SiC/SiC composite tubes: Effect of braiding angle ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation