Passer à la navigation principale Passer à la recherche Passer au contenu principal

Desorption mechanisms in PMMA irradiated by High order Harmonics

  • M. De Grazia
  • , H. Merdji
  • , T. Auguste
  • , B. Carré
  • , J. Gaudin
  • , G. Geoffroy
  • , S. Guizard
  • , F. Krejci
  • , J. Kuba
  • , J. Chalupsky
  • , J. Cihelka
  • , V. Hajkova
  • , M. Ledinský
  • , L. Juha
  • Institut Pierre Simon Laplace, CNRS and CEA
  • Saint-Gobain
  • Laboratoire des Solides Irradiés
  • European XFEL GmbH
  • Czech Technical University in Prague
  • Institute of Physics of the Czech Academy of Sciences

Résultats de recherche: Le chapitre dans un livre, un rapport, une anthologie ou une collectionContribution à une conférenceRevue par des pairs

Résumé

The recent development of intense sources in the XUV range (10-100 nm), such as X-ray laser, Free Electron Laser and High order Harmonics (HoH), allows the study of high flux processes and ultra-fast dynamics in various domains. At the SLIC facility of CEA-Saclay, we have built a gas-harmonic beamline to investigate the interaction of intense XUV pulse with solids. High Harmonics of an IR laser (Ti:Sa at 800 nm, 35 fs, 13 mJ/pulse, 1 kHz) are generated in a rare gas cell (Xe). The useful XUV range (40-60 nm) is selected with metallic filters. The harmonic beam is focused with a parabolic mirror to a 10 μm focal spot on sample, leading to a fluence per shot of up to 1 mJ/cm2 (within a typical 10 fs pulse duration). Studies aimed at understanding the damaging mechanisms caused by XUV irradiation on surface of various samples by systematically varying of fluence and exposure time. For PMMA irradiated in the desorption regime (fluence/shot ≤ 0.2 mJ/cm2), the surface presents craters whose profile depends on the dose (Grey [Gy] = 1 J/kg). The crater evolution proceeds from the competition between two main degradation processes, that is chain scission and cross linking. Namely, at low dose (≤ 1 GGy) polymer chain scission is followed by the blow up of the volatile, molecular fragments, forming the crater. At high dose (> 10 GGy) the broken chain-ends, in the near-surface layer of the remaining material, recombine by cross-linking, opposing desorption by surface hardening. In a recent experiment at LCLS FEL facility, PMMA was irradiated at high fluence; the cross-linking signature was identified from Raman spectroscopy. A kinetic model could be adapted for interpreting these original and very promising results.

langue originaleAnglais
titreDamage to VUV, EUV, and X-Ray Optics III
Les DOIs
étatPublié - 25 juil. 2011
Modification externeOui
EvénementDamage to VUV, EUV, and X-Ray Optics III - Prague, République tchcque
Durée: 18 avr. 201120 avr. 2011

Série de publications

NomProceedings of SPIE - The International Society for Optical Engineering
Volume8077
ISSN (imprimé)0277-786X

Une conférence

Une conférenceDamage to VUV, EUV, and X-Ray Optics III
Pays/TerritoireRépublique tchcque
La villePrague
période18/04/1120/04/11

Empreinte digitale

Examiner les sujets de recherche de « Desorption mechanisms in PMMA irradiated by High order Harmonics ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation