Passer à la navigation principale Passer à la recherche Passer au contenu principal

Experimental and simulation study of the behaviour and operation modes of MSGC + GEM detectors

  • M. Ageron
  • , A. Albert
  • , T. Barvich
  • , W. Beaumont
  • , T. Beckers
  • , K. Bernier
  • , P. Blüm
  • , I. Boulogne
  • , D. Bouvet
  • , J. M. Brom
  • , F. Charles
  • , J. Coffin
  • , D. Contardo
  • , E. Daubie
  • , F. Didierjean
  • , G. De Lentdecker
  • , J. De Troy
  • , O. Devroede
  • , M. Erdmann
  • , J. P. Ernenwein
  • M. Fahrer, G. Flügge, J. C. Fontaine, W. Geist, U. Goerlach, M. Gottschalk, J. M. Helleboid, D. Huss, F. Iacopi, P. Juillot, K. Kärcher, F. Kühn, A. Lounis, C. Maazouzi, D. Macke, C. Martin, L. Mirabito, S. Moreau, T. Müller, D. Neuberger, A. Nowack, S. Perries, I. Ripp-Baudot, F. Röderer, R. Schulte, L. Shekhtman, H. J. Simonis, W. Struczinski, A. Tatarinov, W. H. Thümmel, F. Udo, C. Vander Velde, W. Van Doninck, C. Van Dyck, P. Vanlaer, L. Van Lancker, T. Weiler, A. Zander, A. Zghiche, V. Zhukov
  • Institut de Physique des 2 Infinis de Lyon
  • Université de Haute Alsace
  • Universität Karlsruhe/Forschungszentrum Karlsruhe
  • University of Antwerp
  • University of Louvain
  • Université de Mons
  • Université Paris-Sud
  • Université Libre de Bruxelles
  • Vrjie Universiteit Brussel
  • RWTH Aachen University
  • Budker Institute of Nuclear Physics of the Siberian Branch of the RAS

Résultats de recherche: Contribution à un journalArticleRevue par des pairs

Résumé

A small series production of detector modules made of MicroStrip Gas Counters (MSGC) and a Gas Electron Multiplier (GEM) foil has been exposed to a high-intensity hadron beam. We report about the reproductibility and stability of the detector responses and about the occurrence and consequences of discharges in the detector. The interdependence of the four voltage differences used in the detector has been studied by simulation and with X-ray measurements. Rate dependence of the signal amplitude is observed. The behaviour of the MSGC+GEM is compared to that of a state-of-the-art MSGC. Influence of various parameters on the detector response is investigated.

langue originaleAnglais
Pages (de - à)121-139
Nombre de pages19
journalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume489
Numéro de publication1-3
Les DOIs
étatPublié - 21 août 2002
Modification externeOui

Empreinte digitale

Examiner les sujets de recherche de « Experimental and simulation study of the behaviour and operation modes of MSGC + GEM detectors ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation