Passer à la navigation principale Passer à la recherche Passer au contenu principal

KBr(Eu) scintillator crystals as heavy ion detectors

  • E. Belmont-Moreno
  • , A. Menchaca-Rocha
  • , M. E. Brandan
  • , J. Hernández A.
  • , M. Gonin
  • , K. Hagel
  • , R. Wada
  • , J. B. Natowitz
  • Universidad Nacional Autónoma de México
  • Cyclotron Institute

Résultats de recherche: Contribution à un journalArticleRevue par des pairs

Résumé

The use of KBr(Eu) scintillator crystals for heavy ion detection purposes is considered by first establishing an optimum Eu concentration and then exposing KBr(Eu) samples to E A ≤ 20 MeV, 2 ≤ Z ≤ 7 ions. The optimum Eu doping found here is 0.1 mol%. The KBr(Eu) response to ions is compared with that of a commercial sample CsI(T1). The resolution of KBr(Eu) is found to provide an adequate element separation, although its relative luminosity is considerably smaller than that of CsI(Tl).

langue originaleAnglais
Pages (de - à)85-88
Nombre de pages4
journalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume300
Numéro de publication1
Les DOIs
étatPublié - 1 janv. 1991
Modification externeOui

Empreinte digitale

Examiner les sujets de recherche de « KBr(Eu) scintillator crystals as heavy ion detectors ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation