Passer à la navigation principale Passer à la recherche Passer au contenu principal

Measurement of critical velocities for fluidelastic instability using vibration control

  • Institut Pierre Simon Laplace, CNRS and CEA

Résultats de recherche: Contribution à un journalArticleRevue par des pairs

20 Citations (Scopus)

Résumé

Fluidelastic effects may be responsible for instabilities of heat exchanger tubes when the fluid flow reaches the critical velocity. The fluidelastic phenomenon is usually studied on experimental mock-ups, which may display only one critical velocity. In this paper, a method based on active vibration control is proposed in order to derive several critical velocities for fluidelastic instability corresponding to several different values of damping, which is artificially varied on the same mock-up. Experimental tests are performed on a flexible tube equipped with piezoelectric actuators in a rigid array under air-water crossflow. It is shown that the reduced critical velocities thus obtained fit well in a classical stability map.

langue originaleAnglais
Pages (de - à)341-345
Nombre de pages5
journalJournal of Vibration and Acoustics
Volume122
Numéro de publication4
Les DOIs
étatPublié - 1 janv. 2000

Empreinte digitale

Examiner les sujets de recherche de « Measurement of critical velocities for fluidelastic instability using vibration control ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation