Passer à la navigation principale Passer à la recherche Passer au contenu principal

Megahertz data collection from protein microcrystals at an X-ray free-electron laser

  • Marie Luise Grünbein
  • , Johan Bielecki
  • , Alexander Gorel
  • , Miriam Stricker
  • , Richard Bean
  • , Marco Cammarata
  • , Katerina Dörner
  • , Lars Fröhlich
  • , Elisabeth Hartmann
  • , Steffen Hauf
  • , Mario Hilpert
  • , Yoonhee Kim
  • , Marco Kloos
  • , Romain Letrun
  • , Marc Messerschmidt
  • , Grant Mills
  • , Gabriela Nass Kovacs
  • , Marco Ramilli
  • , Christopher M. Roome
  • , Tokushi Sato
  • Matthias Scholz, Michel Sliwa, Jolanta Sztuk-Dambietz, Martin Weik, Britta Weinhausen, Nasser Al-Qudami, Djelloul Boukhelef, Sandor Brockhauser, Wajid Ehsan, Moritz Emons, Sergey Esenov, Hans Fangohr, Alexander Kaukher, Thomas Kluyver, Max Lederer, Luis Maia, Maurizio Manetti, Thomas Michelat, Astrid Münnich, Florent Pallas, Guido Palmer, Gianpietro Previtali, Natascha Raab, Alessandro Silenzi, Janusz Szuba, Sandhya Venkatesan, Krzysztof Wrona, Jun Zhu, R. Bruce Doak, Robert L. Shoeman, Lutz Foucar, Jacques Philippe Colletier, Adrian P. Mancuso, Thomas R.M. Barends, Claudiu A. Stan, Ilme Schlichting
  • Max Planck Institute for Medical Research
  • European XFEL GmbH
  • University of Rennes
  • c/o DESY
  • BioXFEL STC
  • La Trobe University
  • Laboratoire de Spectrochimie Infrarouge et Raman, Université des Sciences et Technologies de Lille, UMR-CNRS 8516
  • LTHE (UMR 5564 CNRS/IRD/Université de Grenoble)
  • Hungarian Academy of Sciences
  • Rutgers University-Newark Campus

Résultats de recherche: Contribution à un journalArticleRevue par des pairs

104 Citations (Scopus)

Résumé

X-ray free-electron lasers (XFELs) enable novel experiments because of their high peak brilliance and femtosecond pulse duration. However, non-superconducting XFELs offer repetition rates of only 10–120 Hz, placing significant demands on beam time and sample consumption. We describe serial femtosecond crystallography experiments performed at the European XFEL, the first MHz repetition rate XFEL, delivering 1.128 MHz X-ray pulse trains at 10 Hz. Given the short spacing between pulses, damage caused by shock waves launched by one XFEL pulse on sample probed by subsequent pulses is a concern. To investigate this issue, we collected data from lysozyme microcrystals, exposed to a ~15 μm XFEL beam. Under these conditions, data quality is independent of whether the first or subsequent pulses of the train were used for data collection. We also analyzed a mixture of microcrystals of jack bean proteins, from which the structure of native, magnesium-containing concanavalin A was determined.

langue originaleAnglais
Numéro d'article3487
journalNature Communications
Volume9
Numéro de publication1
Les DOIs
étatPublié - 1 déc. 2018
Modification externeOui

Empreinte digitale

Examiner les sujets de recherche de « Megahertz data collection from protein microcrystals at an X-ray free-electron laser ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation