Model-Assisted Time-Synchronization of Cardiac MR Image and Catheter Pressure Data

  • Maria Gusseva
  • , Joshua S. Greer
  • , Daniel A. Castellanos
  • , Mohamed Abdelghafar Hussein
  • , Gerald Greil
  • , Surendranath R. Veeram Reddy
  • , Tarique Hussain
  • , Dominique Chapelle
  • , Radomír Chabiniok
  • INRIA
  • Department of Surgery
  • Boston Children's Hospital and Harvard Medical School
  • Kafrelsheikh University

Résultats de recherche: Le chapitre dans un livre, un rapport, une anthologie ou une collection › Contribution à une conférence › Revue par des pairs

3 Citations (Scopus)

Résumé

When combining cardiovascular magnetic resonance imaging (CMR) with pressure catheter measurements, the acquired image and pressure data need to be synchronized in time. The time offset between the image and pressure data depends on a number of factors, such as the type and settings of the MR sequence, duration and shape of QRS complex or the type of catheter, and cannot be typically estimated beforehand. In the present work we propose using a biophysical heart model to synchronize the left ventricular (LV) pressure and volume (P-V) data. Ten patients, who underwent CMR and LV catheterization, were included. A biophysical model of reduced geometrical complexity with physiologically substantiated timing of each phase of the cardiac cycle was first adjusted to individual patients using basic morphological and functional indicators. The pressure and volume waveforms simulated by the patient-specific models were then used as templates to detect the time offset between the acquired ventricular pressure and volume waveforms. Time-varying ventricular elastance was derived from clinical data both as originally acquired as well as when time-synchronized, and normalized with respect to end-systolic time and maximum elastance value (EorigN(t), Et-synN(t), respectively). Et-synN(t) was significantly closer to the experimentally obtained EexpN(t) published in the literature (p < 0.05, L2 norm). The work concludes that the model-driven time-synchronization of P-V data obtained by catheter measurement and CMR allows to generate high quality P-V loops, which can then be used for clinical interpretation.

langue originaleAnglais
titreFunctional Imaging and Modeling of the Heart - 11th International Conference, FIMH 2021, Proceedings
rédacteurs en chefDaniel B. Ennis, Luigi E. Perotti, Vicky Y. Wang
EditeurSpringer Science and Business Media Deutschland GmbH
Pages362-372
Nombre de pages11
ISBN (imprimé)9783030787097
Les DOIs
étatPublié - 1 janv. 2021
Evénement11th International Conference on Functional Imaging and Modeling of the Heart, FIMH 2021 - Virtual, Online
Durée: 21 juin 2021 → 25 juin 2021

Série de publications

NomLecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
Volume12738 LNCS
ISSN (imprimé)0302-9743
ISSN (Electronique)1611-3349

Une conférence

Une conférence11th International Conference on Functional Imaging and Modeling of the Heart, FIMH 2021
La villeVirtual, Online
période21/06/21 → 25/06/21

Empreinte digitale

Examiner les sujets de recherche de « Model-Assisted Time-Synchronization of Cardiac MR Image and Catheter Pressure Data ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation