Passer à la navigation principale Passer à la recherche Passer au contenu principal

Modified cantilevers to probe unambiguously out-of-plane piezoresponse

  • Natalia Alyabyeva
  • , Aimeric Ouvrard
  • , Ionela Lindfors-Vrejoiu
  • , Alexey Kolomiytsev
  • , Maxim Solodovnik
  • , Oleg Ageev
  • , Damien McGrouther
  • Université Paris-Saclay
  • II. Physikalisches Institut
  • Germany; University of Cologne
  • Department of Nanotechnologies and Microsystems Technology
  • Southern Federal University
  • Research and Educational Centre Nanotechnology
  • SUPA
  • University of Glasgow

Résultats de recherche: Contribution à un journal › Article › Revue par des pairs

3 Citations (Scopus)

Résumé

We demonstrate and investigate the coupling of contributions from both in-plane (IP) polarization and out-of-plane (OP) components in BiFeO3 (BFO) thin-film polarization probed by piezoresponse force microscopy (PFM). Such coupling leads to image artifacts which prevent the correct determination of OP polarization vector directions and the corresponding piezoelectric coefficient d33. Using material strength theory with a one-dimensional modeling of the cantilever oscillation amplitude under electrostatic and elastic forces as a function of the tip length, we have evidenced the impact of IP piezoresponse to the OP signal for tip length longer than 4 μm. The IP polarization vector induces a significant longitudinal bending of the cantilever, due to the small spring constant of long tips, which provokes a normal deviation superimposed to the OP piezoresponse. These artifacts can be reduced by increasing the longitudinal spring constant of the cantilever by shortening the tip length. Standard cantilevers with 15-μm-long tips were modified to reach the desired tip length, using focused ion-beam techniques and tested using PFM on the same BFO thin film. Tip length shortening has strongly reduced IP artifacts as expected, while the impact of nonlocal electrostatic forces, becoming predominant for tips shorter than 1 μm, has led to a non-negligible deflection offset. For shorter tips, a strong electric field from a cantilever beam can induce polarization switching as observed for a 0.5-μm-long tip. Tip length ranging from 1 to 4 μm allowed minimizing both artifacts to probe unambiguously OP piezoresponse and quantify the d33 piezoelectric coefficient.

langue originaleAnglais
Numéro d'article064402
journalPhysical Review Materials
Volume2
Numéro de publication6
Les DOIs
étatPublié - 4 juin 2018
Modification externeOui

Empreinte digitale

Examiner les sujets de recherche de « Modified cantilevers to probe unambiguously out-of-plane piezoresponse ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation