Passer à la navigation principale Passer à la recherche Passer au contenu principal

Overview of the ECAL off-detector electronics of the CMS experiment

  • R. Alemany
  • , C. B. Almeida
  • , N. Almeida
  • , M. Bercher
  • , R. Benetta
  • , V. Bexiga
  • , J. Bourotte
  • , Ph Busson
  • , N. Cardoso
  • , M. Cerrutti
  • , M. Dejardin
  • , J. L. Faure
  • , O. Gachelin
  • , M. Gastal
  • , Y. Geerebaert
  • , J. Gilly
  • , Ph Gras
  • , M. Hansen
  • , M. Husejko
  • , A. Jain
  • A. Karar, K. Kloukinas, C. Ljuslin, P. Machado, I. Mandjavidze, M. Mur, P. Paganini, N. Regnault, M. Santos, J. C. Da Silva, I. Teixeira, J. P. Teixeira, J. Varela, P. Verrecchia, L. Zlatevski
  • LIP - Lisboa
  • Universidade de Lisboa
  • European Organization for Nuclear Research
  • Institut Pierre Simon Laplace, CNRS and CEA
  • Warsaw University of Technology
  • Academy of Science

Résultats de recherche: Contribution à un journal › Article de révision › Revue par des pairs

7 Citations (Scopus)

Résumé

Located between the on-detector front-end electronics and the global data acquisition system (DAQ), the off-detector electronics of the CMS electromagnetic calorimeter (ECAL) is involved in both detector readout and trigger system. Working at 40 MHz, the trigger part must, within ten clock cycles, receive and deserialize the data of the front-end electronics, encode the trigger primitives using a nonlinear scale, assure time alignment between channels using a histogramming technique and send the trigger primitives to the regional trigger. In addition, it must classify trigger towers in three classes of interest and send this classification to the readout part. The readout part must select the zero suppression level to be applied depending on the regions of interest determined from the trigger tower classification, deserialize front-end data coming from high-speed (800 Mb/s) serial links, check their integrity, apply zero suppression, build the event and send it to the DAQ, monitor the buffer occupancy and send back pressure to the trigger system when required, provide data spying and monitoring facilities for the local DAQ. The system, and especially the data link speed, the latency constraints and the bit-error rate requirements have been validated on prototypes. Part of the system is about to go to production.

langue originaleAnglais
Pages (de - à)1918-1924
Nombre de pages7
journalIEEE Transactions on Nuclear Science
Volume52
Numéro de publication5 III
Les DOIs
étatPublié - 1 oct. 2005

Empreinte digitale

Examiner les sujets de recherche de « Overview of the ECAL off-detector electronics of the CMS experiment ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation