Résumé
This paper presents a six-port reflectometer in the W frequency band (75-110 GHz). Schottky diodes, operating in AC detection mode, are used as power detectors. A linearization procedure is used to improve the measurement accuracy. The six-port calibration is performed with two standards. Finally, the experimental results are compared with those obtained with other network analyzers in this frequency band.
| Titre traduit de la contribution | Design and evaluation of a millimeter wave six-port reflectometer in the w frequency band (75-110 ghz) |
|---|---|
| langue originale | Français |
| Pages (de - à) | 536-538 |
| Nombre de pages | 3 |
| journal | Annales des Telecommunications/Annals of Telecommunications |
| Volume | 47 |
| Numéro de publication | 11-12 |
| Les DOIs | |
| état | Publié - 1 nov. 1992 |
mots-clés
- Calibration
- Microwave reflectometer
- Millimetric wave
- Multipole circuit
- Network analyzer
Empreinte digitale
Examiner les sujets de recherche de « Réalisation ďun Réflectomètre a Six Accès Dans la Bande de Fréquences Millimétriques W (75-110 GHz) ». Ensemble, ils forment une empreinte digitale unique.Contient cette citation