Passer à la navigation principale Passer à la recherche Passer au contenu principal

Skin dosimetry in megavoltage radiotherapy using hydrogenated amorphous silicon on a tissue-equivalent flexible substrate

  • Aishah Bashiri
  • , Cameron Anderson
  • , Jessie Posar
  • , Shane Pavitt
  • , Yashiv Dookie
  • , Joanne McNamara
  • , Rabia Sandhu
  • , Saba Aziz
  • , Lucio Calcagnile
  • , Daniela Calvo
  • , Domenico Caputo
  • , Anna Paola Caricato
  • , Roberto Catalano
  • , Massimo Cazzanelli
  • , Roberto Cirio
  • , Giuseppe Antonio Pablo Cirrone
  • , Federico Cittadini
  • , Tommaso Croci
  • , Giacomo Cuttone
  • , Gianpiero de Cesare
  • Paolo de Remigis, Sylvain Dunand, Michele Fabi, Luca Frontini, Catia Grimani, Mariacristina Guarrera, Hamza Hasnaoui, Giacomo Insero, Maria Ionica, Keida Kanxheri, Georgios Konstantinou, Francesca Lenta, Valentino Liberali, Loris Barraud, Nicola Lovecchio, Marta Ponzecchi, Giuseppe Maruccio, Maurizio Martino, Giovanni Mazza, Mauro Menichelli, Anna Grazia Monteduro, Arianna Morozzi, Augusto Nascetti, Stefania Pallotta, Daniele Passeri, Maddalena Pedio, Giada Petringa, Francesca Peverini, Pisana Placidi, Matteo Polo, Alberto Quaranta, Gianluca Quarta, Silvia Rizzato, Federico Sabbatini, Leonello Servoli, Alberto Stabile, Cinzia Talamonti, Luca Tosti, Monica Setia Vasquez Mora, Alberto Verdini, Mattia Villani, Richard James Wheadon, Nicolas Wyrsch, Marco Petasecca
  • University of Wollongong
  • Najran University
  • Shoalhaven Cancer Care Centre
  • Sezione di Lecce
  • University of Salento
  • INFN Sezione di Torino
  • Sezione di Roma
  • University of Rome “Tor Vergata”
  • INFN-LNS
  • Trento Institute for Fundamental Physics and Applications
  • INFN Sezione di Perugia
  • University of Padova
  • ENAC-IIC-GEL
  • University of Urbino Carlo Bo
  • Istituto Nazionale di Fisica Nucleare, Sezione di Firenze
  • Sezione INFN di Milano
  • University of Milano
  • University of Florence
  • University of Perugia
  • Politecnico di Torino
  • International School for Advanced Studies (SISSA/ISAS)

Résultats de recherche: Contribution à un journal › Article › Revue par des pairs

Résumé

Acute skin toxicity after radiation treatments highlights the need for improved dose monitoring and measurement, as the treatment planning system does not accurately estimate skin dose. Wearable radiation detectors may be the solution for most in vivo dosimetry needs, but they require innovative materials. The purpose of this work is to overcome the challenges that limit accurate skin dosimetry by exploring the use of hydrogenated amorphous silicon (a-Si:H) fabricated on a flexible polyimide substrate for direct radiation detection. The a-Si:H detector was fabricated on a 125 μm polyimide substrate with a thickness of 3.6–10 μm. The detector’s response to the build-up region of the percentage depth dose (PDD) of the MV photon beam was compared to Geant4 radiation transport simulations and benchmarked to Attix ionization chamber measurements. Angular dependency and surface field factors at the phantom surface were compared to Attix IC. The PDD measurement is within 2% of Geant4’s simulation and the Attix chamber’s response from 150 (Formula presented) (Formula presented) m to 25 mm in a plastic water phantom. All samples showed linear dose responses with 0.37% reproducibility. The a-Si:H device matches the Attix chamber for surface field factor measurements (6–10 MV photon beams, for 5 to 25 cm field sizes). The angular dependence (−60° to +60°) compared to the Attix IC confirms the sensor’s WED of 150 ± 5 µm. This study demonstrates that a-Si:H sensors on flexible plastic substrates have a potential for accurate surface dose measurements and agree with reference detectors. This thin, flexible detector provides real time measurements and is stable under high radiation doses. The possibility to assemble with ease an array of a-Si:H pixels over large areas with different sizes and shapes, makes this technology attractive for in vivo dosimetry.

langue originaleAnglais
Numéro d'article155020
journalPhysics in Medicine and Biology
Volume71
Numéro de publication15
Les DOIs
étatPublié - 14 août 2026
Modification externeOui

Empreinte digitale

Examiner les sujets de recherche de « Skin dosimetry in megavoltage radiotherapy using hydrogenated amorphous silicon on a tissue-equivalent flexible substrate ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation