Passer à la navigation principale Passer à la recherche Passer au contenu principal

SPACIROC3: A low power 100MHz photon Counting ASIC for cosmic ray observatory

  • CNRS
  • University of Turin

Résultats de recherche: Le chapitre dans un livre, un rapport, une anthologie ou une collectionContribution à une conférenceRevue par des pairs

2 Citations (Scopus)

Résumé

SPACIROC (Spatial Photomultiplier Array Counting and Integrating ReadOut Chip) is the front-end ASIC designed for the space-borne fluorescent telescope JEM-EUSO (Extreme Universe Space Observatory onboard Japanese Experiment Module). This ASIC is dedicated to readout 64-channel Multi-Anode Photo-Multiplier Tube (MAPMT). The two main features are the photon counting for each input and the charge conversion for each 8-channel sum. In the photon counting mode, 100% trigger efficiency is achieved for 1/3 photo-electron (p.e.) input charges. In order to avoid pile-up in the case of a large flux of photons, the double pulse separation must be shorter than 10 ns. The high-speed performance is obtained with a low power consumption (1 mW/channel) thanks to the SiGe technology and by integrating photo-electron trigger counters and a dedicated design to improve the double pulse separation up to 100 MHz. For the charge measurement, the ASIC should operate with a large dynamic range (1 p.e. to 100 p.e. per pixel). SPACIROC3 has been designed to improve the double pulse resolution compared to the previous version, which was extensively used in the EUSO balloon campaign of 2014. The architecture and the performance of the photon counting part will be detailed in this presentation.

langue originaleAnglais
titre2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016
EditeurInstitute of Electrical and Electronics Engineers Inc.
ISBN (Electronique)9781509016426
Les DOIs
étatPublié - 16 oct. 2017
Evénement2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016 - Strasbourg, France
Durée: 29 oct. 20166 nov. 2016

Série de publications

Nom2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016
Volume2017-January

Une conférence

Une conférence2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016
Pays/TerritoireFrance
La villeStrasbourg
période29/10/166/11/16

Empreinte digitale

Examiner les sujets de recherche de « SPACIROC3: A low power 100MHz photon Counting ASIC for cosmic ray observatory ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation