Passer à la navigation principale Passer à la recherche Passer au contenu principal

Sparsity Constrained Linear Tangent Space Alignment Model (LTSA) for 3d Cardiac Extracellular Volume Mapping

  • Ismael B.G. Mounime
  • , Wonil Lee
  • , Thibault Marin
  • , Paul K. Han
  • , Yanis Djebra
  • , Samira V. Eslahi
  • , Pietro Gori
  • , Elsa Angelini
  • , Georges El Fakhri
  • , Chao Ma

Résultats de recherche: Le chapitre dans un livre, un rapport, une anthologie ou une collectionContribution à une conférenceRevue par des pairs

Résumé

Cardiac longitudinal relaxation time (T1) and extracellular volume (ECV) are valuable bio-markers used for the quantitative characterization of cardiac tissue properties, showing great potential in many clinical applications such as diffuse fibrosis. However, cardiac T1 and ECV mapping is difficult because of respiratory and cardiac motions. A unique challenge for post-contrast T1 mapping is that the concentration of contrast agent also changes over time. Recently, a linear tangent space alignment (LTSA) model-based fast MRI method has been proposed to enable high-resolution, high-frame-rate dynamic MR with sparsely sampled (k, t)-space data by leveraging the intrinsic low-dimensional manifold structure of dynamic MR images, showing superior performance over the low-rank model-based methods. This work extends the LTSA method by imposing an additional sparsity constraint on the subspace alignment matrix of the LTSA model for improved image reconstruction. The performance of the proposed method is validated in 3D free-breathing, pre- and post-contrast cardiac T1 mapping as well as ECV mapping using in vivo data acquired on healthy volunteers at 3T.

langue originaleAnglais
titreIEEE International Symposium on Biomedical Imaging, ISBI 2024 - Conference Proceedings
EditeurIEEE Computer Society
ISBN (Electronique)9798350313338
Les DOIs
étatPublié - 1 janv. 2024
Evénement21st IEEE International Symposium on Biomedical Imaging, ISBI 2024 - Athens, Grcce
Durée: 27 mai 202430 mai 2024

Série de publications

NomProceedings - International Symposium on Biomedical Imaging
ISSN (imprimé)1945-7928
ISSN (Electronique)1945-8452

Une conférence

Une conférence21st IEEE International Symposium on Biomedical Imaging, ISBI 2024
Pays/TerritoireGrcce
La villeAthens
période27/05/2430/05/24

Empreinte digitale

Examiner les sujets de recherche de « Sparsity Constrained Linear Tangent Space Alignment Model (LTSA) for 3d Cardiac Extracellular Volume Mapping ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation