Passer à la navigation principale Passer à la recherche Passer au contenu principal

Test results of a fully projective lead/scintillating-fiber calorimeter

  • J. Badier
  • , N. Bouhemaid
  • , S. Buontempo
  • , P. Busson
  • , L. Calôba
  • , P. Cattaneo
  • , C. Charlot
  • , A. Chekhtman
  • , M. C. Cousinou
  • , S. Dagoret
  • , A. Dell'Acqua
  • , E. Duchovni
  • , A. Ereditato
  • , R. Ferrari
  • , D. Fouchez
  • , L. Fredj
  • , G. Fumagalli
  • , J. M. Gaillard
  • , G. Goggi
  • , A. Gomes
  • T. Hansl-Kozanecka, A. Henriques, P. Jenni, F. Kovacs, D. Lellouch, L. Levinson, L. Linssen, M. Livan, J. Lory, N. Lupu, A. Maio, B. Michel, G. Mikenberg, G. Montarou, R. Nacasch, E. Nagy, D. Pallin, E. Pennacchio, L. Peralta, L. Poggioli, G. Polesello, F. Riccardi, A. Rimoldi, J. M. Seixas, M. N. Souza, Z. D. Thomé, S. Tisserant, B. Tomé, F. Vazeille, V. Vercesi, R. Wigmans, R. Zitoun
  • Clermont-Auvergne University
  • University of Naples Federico II
  • Instituto de Biofisica da UFRJ
  • University of Pavia
  • Aix-Marseille Université
  • Universités Paris VI and VII
  • Weizmann Institute of Science Israel
  • European Organization for Nuclear Research
  • Laboratoire de l'Accélérateur Linéaire
  • LIP - Lisboa
  • Centro de Física Nuclear da Universidade de Lisboa
  • Texas Tech University

Résultats de recherche: Contribution à un journalArticleRevue par des pairs

Résumé

We report on an experimental study of the properties of a modular lead/scintillating-fiber calorimeter with a fully projective tower geometry. Although the calorimeter structure is monolythic, an effective segmentation into an electromagnetic and an hadronic section is achieved by separating the readout of the fibers running throughout the calorimeter from those starting beyond a depth of ∼ 25 radiation lengths. This feature is used for e/π separation. Discontinuities in the sampling fraction near the boundaries of the modules cause a signal nonuniformity for electrons, which can be corrected. Similar effects observed for high energy hadrons are discussed. Results are given on the energy and position resolution for electrons, on the signal linearity and on the absolute light yield. Pion showers were only partially contained in this detector. The information from a backing calorimeter, consisting of fast thin-gap wire chambers interleaved by iron slabs, significantly improves the energy resolution of the incompletely contained pion showers.

langue originaleAnglais
Pages (de - à)326-341
Nombre de pages16
journalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume337
Numéro de publication2-3
Les DOIs
étatPublié - 1 janv. 1994

Empreinte digitale

Examiner les sujets de recherche de « Test results of a fully projective lead/scintillating-fiber calorimeter ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation