Passer à la navigation principale Passer à la recherche Passer au contenu principal

The H 1 liquid argon calorimeter system

  • B. Andrieu
  • , A. Babayev
  • , J. Bán
  • , E. Banas
  • , E. Barrelet
  • , U. Bassler
  • , D. Bederede
  • , R. Bernard
  • , G. Bernardi
  • , R. Bernier
  • , M. Besançon
  • , J. C. Biasci
  • , E. Binder
  • , F. Blouzon
  • , H. Blume
  • , K. Borras
  • , V. Boudry
  • , F. Brasse
  • , D. Breton
  • , H. Brettel
  • V. Brisson, D. Bruncko, U. Buchner, A. Busata, G. Buschhorn, A. J. Campbell, T. Carli, F. Charles, R. Chase, M. Colombo, Ch Coutures, A. Coville, G. Cozzika, J. Cvach, M. Danilov, M. David, J. David, B. Delcourt, L. Del Buono, F. Descamps, M. Devel, A. DeRoeck, P. Dingus, K. Djidi, A. Drescher, U. Dretzler, M. Drewe, J. Duboc, F. Dupont, V. Efremenko, F. Eisele, G. Ernst, G. Falley, R. Fang, J. Feltesse, Z. Y. Feng, J. Fent, J. Ferencei, W. Flauger, G. Flügge, J. Formánek, W. Fröchtenicht, K. Gamerdinger, J. Gayler, I. Giesgen, J. Godlewski, L. Goerlich, M. Goldberg, P. Goritchev, L. Gosset, R. Grässler, C. Gregory, H. Greif, G. Grindhammer, M. Haguenauer, L. Hajduk, O. Hamon, P. Hartz, R. Haydar, I. Herynek, W. Hildesheim, J. Hladký, J. Huber, N. Huot, J. F. Huppert, D. Imbault, M. A. Jabiol, A. Jacholkowska, M. Jaffré, J. Jeanjean, H. Jung, C. Kiesling, M. Kolander, H. Kolanoski, J. Koll, V. Korbel, M. Korn, W. Krasny, M. Kubantsev, J. P. Kubenka, H. Küster, M. Kuhlen, T. Kurča, J. Kurzhöfer, J. F. Laporte, H. Laskus, M. Lemler, U. Lenhardt, P. Loch, D. Lüers, E. Malinovski, J. Marks, F. Martin, J. Martyniak, T. Merz, S. Mikocki, E. Monnier, B. Montés, P. Murín, V. Nagovizin, P. Nayman, A. Nepeipivo, H. K. Nguyen, H. Novakova, G. Nowak, H. Oberlack, U. Obrock, P. Pailler, J. Y. Parey, C. Pascaud, P. Perrodo, S. Peters, J. P. Pharabod, W. Pimpl, K. Rauschnabel, A. Reboux, P. Reimer, P. Ribarics, M. Rietz, M. Rudowicz, S. Rusakov, V. Rusinov, K. Rybicki, N. Sahlmann, M. Savitsky, P. Sawallisch, P. Schacht, W. Schmitz, H. Schmücker, M. Seman, V. Shekelyan, I. Sheviakov, Y. Sirois, P. Smirnov, J. Špalek, J. Staeck, P. Staroba, P. Štefan, H. Steiner, J. Stier, J. Strachota, K. Thiele, I. Tichomirov, W. Tribanek, V. Tschernyshov, M. Turiot, J. Turnau, L. Urban, M. Urban, S. Valkar, A. Valkarova, C. Vallée, M. Vecko, P. Verrecchia, G. Villet, D. Wegener, P. Weissbach, H. P. Wellisch, T. P. Yiou, J. Ẑáček, P. Závada, Ch Zeitnitz, F. Zomer
  • Institute for Theoretical and Experimental Physics
  • Institute of Experimental Physics Slovak Academy of Sciences
  • Universités Paris VI and VII
  • Institut Pierre Simon Laplace, CNRS and CEA
  • Laboratoire de l'Accélérateur Linéaire
  • c/o DESY
  • Max-Planck-Institut für Physik
  • University of Dortmund
  • RWTH Aachen University
  • Charles University
  • Institute for Nuclear Physics
  • Institute of Physics of the Czech Academy of Sciences
  • P.N. Lebedev Physical Institute of the Russian Academy of Sciences

Résultats de recherche: Contribution à un journalArticleRevue par des pairs

153 Citations (Scopus)

Résumé

The liquid argon calorimeter of the H 1 detector presently taking data at the HERA ep collider at DESY, Hamburg, is described. The main physics requirements and the most salient design features relevant to this calorimeter are given. The aim to have smooth and hermetic calorimetric coverage over the polar angular range 4° ≤ θ ≤ 154° is achieved by a single liquid argon cryostat containing calorimeter stacks structured in wheels and octants for easy handling. The absorber materials used are lead in the electromagnetic part and stainless steel in the hadronic part. The read-out system is pipelined to reduce the dead time induced by the high trigger rate expected at the HERA collider where consecutive bunches are separated in time by 96 ns. The main elements of the calorimeter, such as the cryostat, with its associated cryogenics, the stack modules, the read-out, calibration and trigger electronics as well as the data acquisition system are described. Performance results from data taken in calibration runs with full size H 1 calorimeter stacks at a CERN test beam, as well as results from data collected with the complete H 1 detector using cosmic rays during the initial phase of ep operations are presented. The observed energy resolutions and linearities are well in agreement with the requirements.

langue originaleAnglais
Pages (de - à)460-498
Nombre de pages39
journalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume336
Numéro de publication3
Les DOIs
étatPublié - 1 déc. 1993

Empreinte digitale

Examiner les sujets de recherche de « The H 1 liquid argon calorimeter system ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation