Passer à la navigation principale Passer à la recherche Passer au contenu principal

The Qweak experimental apparatus

  • T. Allison
  • , M. Anderson
  • , D. Androić
  • , D. S. Armstrong
  • , A. Asaturyan
  • , T. Averett
  • , R. Averill
  • , J. Balewski
  • , J. Beaufait
  • , R. S. Beminiwattha
  • , J. Benesch
  • , F. Benmokhtar
  • , J. Bessuille
  • , J. Birchall
  • , E. Bonnell
  • , J. D. Bowman
  • , P. Brindza
  • , D. B. Brown
  • , R. D. Carlini
  • , G. D. Cates
  • B. Cavness, G. Clark, J. C. Cornejo, S. Covrig Dusa, M. M. Dalton, C. A. Davis, D. C. Dean, W. Deconinck, J. Diefenbach, K. Dow, J. F. Dowd, J. A. Dunne, D. Dutta, W. S. Duvall, J. R. Echols, M. Elaasar, W. R. Falk, K. D. Finelli, J. M. Finn, D. Gaskell, M. T.W. Gericke, J. Grames, V. M. Gray, K. Grimm, F. Guo, J. Hansknecht, D. J. Harrison, E. Henderson, J. R. Hoskins, E. Ihloff, K. Johnston, D. Jones, M. Jones, R. Jones, M. Kargiantoulakis, J. Kelsey, N. Khan, P. M. King, E. Korkmaz, S. Kowalski, A. Kubera, J. Leacock, J. P. Leckey, A. R. Lee, J. H. Lee, L. Lee, Y. Liang, S. Macewan, D. Mack, J. A. Magee, R. Mahurin, J. Mammei, J. W. Martin, A. McCreary, M. H. McDonald, M. J. McHugh, P. Medeiros, D. Meekins, J. Mei, R. Michaels, A. Micherdzinska, A. Mkrtchyan, H. Mkrtchyan, N. Morgan, J. Musson, K. E. Mesick, A. Narayan, L. Z. Ndukum, V. Nelyubin, Nuruzzaman, W. T.H. Van Oers, A. K. Opper, S. A. Page, J. Pan, K. D. Paschke, S. K. Phillips, M. L. Pitt, M. Poelker, J. F. Rajotte, W. D. Ramsay, W. R. Roberts, J. Roche, P. W. Rose, B. Sawatzky, T. Seva, M. H. Shabestari, R. Silwal, N. Simicevic, G. R. Smith, S. Sobczynski, P. Solvignon, D. T. Spayde, B. Stokes, D. W. Storey, A. Subedi, R. Subedi, R. Suleiman, V. Tadevosyan, W. A. Tobias, V. Tvaskis, E. Urban, B. Waidyawansa, P. Wang, S. P. Wells, S. A. Wood, S. Yang, S. Zhamkochyan, R. B. Zielinski
  • Thomas Jefferson National Accelerator Facility
  • University of Manitoba
  • ENAC-IIC-GEL
  • University of Zagreb
  • College of William and Mary
  • Yerevan Physics Institute
  • Massachusetts Institute of Technology
  • Ohio University
  • Christopher Newport University
  • Duquesne University
  • TRIUMF
  • Virginia Polytechnic Institute and State University
  • MST-8, Los Alamos National Laboratory
  • Mississippi State University
  • University of Virginia
  • Angelo State University
  • Hampton University
  • Southern University at New Orleans
  • Louisiana Tech University
  • Berthold Technologies
  • University of Winnipeg
  • University of Connecticut
  • University of Northern British Columbia
  • Kent State University
  • Indiana University Bloomington
  • Institute for Basic Science (IBS)
  • George Washington University
  • Middle Tennessee State University
  • University of Pittsburgh
  • CGG Veritas
  • State University of New Jersey
  • Rutgers University–New Brunswick
  • University of New Hampshire Durham
  • Hendrix College
  • University of California, Berkeley

Résultats de recherche: Contribution à un journal › Article › Revue par des pairs

41 Citations (Scopus)

Résumé

The Jefferson Lab Qweak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise e→p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 μA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Møller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8° and 11.6° were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cherenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q2=0.025 GeV2 was determined using dedicated low-current (~100pA) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet.

langue originaleAnglais
Pages (de - à)105-133
Nombre de pages29
journalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume781
Les DOIs
étatPublié - 1 mai 2015
Modification externeOui

Empreinte digitale

Examiner les sujets de recherche de « The Qweak experimental apparatus ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation