Passer à la navigation principale Passer à la recherche Passer au contenu principal

The THEMIS magnetic cleanliness program

  • M. Ludlam
  • , V. Angelopoulos
  • , E. Taylor
  • , R. C. Snare
  • , J. D. Means
  • , Y. S. Ge
  • , P. Narvaez
  • , H. U. Auster
  • , O. Le Contel
  • , D. Larson
  • , T. Moreau
  • University of California, Space Sciences Laboratory
  • University of California, Los Angeles
  • Science Division
  • Technical University Braunschweig
  • (CNRS/UVSQ/UPMC)

Résultats de recherche: Contribution à un journalArticleRevue par des pairs

Résumé

The five identical THEMIS Spacecraft, launched in February 2007, carry two magnetometers on each probe, one DC fluxgate (FGM) and one AC search coil (SCM). Due to the small size of the THEMIS probes, and the short length of the magnetometer booms, magnetic cleanliness was a particularly complex task for this medium sized mission. The requirements leveled on the spacecraft and instrument design required a detailed approach, but one that did not hamper the development of the probes during their short design, production and testing phase. In this paper we describe the magnetic cleanliness program's requirements, design guidelines, program implementation, mission integration and test philosophy and present test results, and mission on-orbit performance.

langue originaleAnglais
Pages (de - à)171-184
Nombre de pages14
journalSpace Science Reviews
Volume141
Numéro de publication1-4
Les DOIs
étatPublié - 1 déc. 2008
Modification externeOui

Empreinte digitale

Examiner les sujets de recherche de « The THEMIS magnetic cleanliness program ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation