Résumé
The 3ω method is a standard way to measure the thermal conductivity of thin films. In this study, we apply the method to read the magnetic state of a perpendicularly magnetized CoTb ferrimagnetic Hall cross using a thermal excitation. In order to generate the thermal excitation, an oscillating current at an ω frequency is applied to the Hall cross using different geometries. The magnetic signals oscillating at ω, 2ω, and 3ω are probed using a lock-in technique. From the analysis of the power dependence, we can attribute the 3ω response to the temperature oscillation and the 2ω to the temperature-gradient oscillation. Finally, the frequency dependence of the magnetic signals can be understood by considering the heat diffusion in a two-dimensional model.
| langue originale | Anglais |
|---|---|
| Numéro d'article | 034028 |
| journal | Physical Review Applied |
| Volume | 9 |
| Numéro de publication | 3 |
| Les DOIs | |
| état | Publié - 27 mars 2018 |
| Modification externe | Oui |
Empreinte digitale
Examiner les sujets de recherche de « Towards Thermal Reading of Magnetic States in Hall Crosses ». Ensemble, ils forment une empreinte digitale unique.Contient cette citation
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver