Une methode de calibration simultanee des accelerometres et des pots vibrants dans le plan transversal

  • CNRS

Résultats de recherche: Le chapitre dans un livre, un rapport, une anthologie ou une collectionContribution à une conférenceRevue par des pairs

Résumé

The cross-axis sensitivity of accelerometers that is of the order of a few hundredths of the main axis sensitivity, is a common concern in vibration measurements. Usually the manufacturers do not provide a complete information upon the transverse sensitivity of transducers. The transverse motion of mechanical shakers is subject to the same problem and lack of information. The method that we present here is aimed at calibrating at the same time both defaults relatively to the axial components. By mounting an accelerometer on a shaker so that the main motion is perpendicular to the main sensitivity, its response adds up two products of the same order of magnitude: the main motion x the cross-axis sensitivity and the main sensitivity x the transverse motion. These two quantities are separated when the accelerometer rotates around the main-motion axis. All relative components of transverse motion and cross-axis sensitivity are derived from a combination of orientations of the accelerometer relatively to the main-motion axis. Measurements made with a variety of accelerometers exhibit a good consistency of the results concerning the transverse motion of a given shaker. Conversely, a good reproducibility of results pertaining to the cross-axis sensitivity of accelerometers has been achieved. The range in which that method is easily used with good results is limited in the low-frequency region by the motion of the shaker base and attachment.

Titre traduit de la contributionMethod of simultaneous calibration of accelerometers and mechanical shakers in the transverse plane
langue originaleFrançais
titreJournal De Physique
rédacteurs en chef Anon
EditeurPubl by Editions de Physique
Pages267-270
Nombre de pages4
Volume4
Edition5 pt 1
ISBN (imprimé)2868832164
étatPublié - 1 mai 1994
EvénementProceedings of the 3rd French Conference on Acoustics. Part 1 (of 2) - Toulouse, Fr
Durée: 2 mai 19946 mai 1994

Une conférence

Une conférenceProceedings of the 3rd French Conference on Acoustics. Part 1 (of 2)
La villeToulouse, Fr
période2/05/946/05/94

Empreinte digitale

Examiner les sujets de recherche de « Une methode de calibration simultanee des accelerometres et des pots vibrants dans le plan transversal ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation