Validation of a novel Multi-Gas sensor for volcanic HCl alongside H2S and SO2 at Mt. Etna

  • T. J. Roberts
  • , T. Lurton
  • , G. Giudice
  • , M. Liuzzo
  • , A. Aiuppa
  • , M. Coltelli
  • , D. Vignelles
  • , G. Salerno
  • , B. Couté
  • , M. Chartier
  • , R. Baron
  • , J. R. Saffell
  • , B. Scaillet
  • Service d'Aéronomie
  • Istituto Nazionale di Geofisica e Vulcanologia, Palermo
  • University of Palermo
  • Istituto Nazionale di Geofisica e Vulcanologia (INGV)
  • Alphasense Ltd, Great Notley
  • BRGM

Résultats de recherche: Contribution à un journalArticleRevue par des pairs

31 Citations (Scopus)

Résumé

Volcanic gas emission measurements inform predictions of hazard and atmospheric impacts. For these measurements, Multi-Gas sensors provide low-cost in situ monitoring of gas composition but to date have lacked the ability to detect halogens. Here, two Multi-Gas instruments characterized passive outgassing emissions from Mt. Etna’s (Italy) three summit craters, Voragine (VOR), North-east Crater (NEC) and Bocca Nuova (BN) on 2 October 2013. Signal processing (Sensor Response Model, SRM) approaches are used to analyse H2S/SO2 and HCl/SO2 ratios. A new ability to monitor volcanic HCl using miniature electrochemical sensors is here demonstrated. A “direct-exposure” Multi-Gas instrument contained SO2, H2S and HCl sensors, whose sensitivities, cross-sensitivities and response times were characterized by laboratory calibration. SRM analysis of the field data yields H2S/SO2 and HCl/SO2 molar ratios, finding H2S/SO2 = 0.02 (0.01–0.03), with distinct HCl/SO2 for the VOR, NEC and BN crater emissions of 0.41 (0.38–0.43), 0.58 (0.54–0.60) and 0.20 (0.17–0.33). A second Multi-Gas instrument provided CO2/SO2 and H2O/SO2 and enabled cross-comparison of SO2. The Multi-Gas-measured SO2-HCl-H2S-CO2-H2O compositions provide insights into volcanic outgassing. H2S/SO2 ratios indicate gas equilibration at slightly below magmatic temperatures, assuming that the magmatic redox state is preserved. Low SO2/HCl alongside low CO2/SO2 indicates a partially outgassed magma source. We highlight the potential for low-cost HCl sensing of H2S-poor HCl-rich volcanic emissions elsewhere. Further tests are needed for H2S-rich plumes and for long-term monitoring. Our study brings two new advances to volcano hazard monitoring: real-time in situ measurement of HCl and improved Multi-Gas SRM measurements of gas ratios.

langue originaleAnglais
Numéro d'article36
journalBulletin of Volcanology
Volume79
Numéro de publication5
Les DOIs
étatPublié - 1 mai 2017
Modification externeOui

Empreinte digitale

Examiner les sujets de recherche de « Validation of a novel Multi-Gas sensor for volcanic HCl alongside H2S and SO2 at Mt. Etna ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation